Detail of Frequency Band

Band 862 – 890 MHz

Part of RSUP RSUP-P/10
Service Mobile except Aeronautical Mobile
Category of assignment Primary
Non-civil utilisation Secondary
Civil utilisation Primary
Note 5.317A
Application Digital cellular
Section 862 – 863 MHz
Additional information Guard band. Not used.
Future The Office will decide on utilisation in accordance with the European harmonisation.
Application Digital cellular
Section 870 – 876 MHz
Additional information Not used.
Future The Office will decide on utilisation in accordance with the European harmonisation. Future Rail Mobile Communication System is under study in the range 874.4-876 MHz.
Application GSM-R
Section 876 – 880 MHz
Harmonisations CEPT/ECC/DEC/(02)05, CEPT/ERC T/R 25-09
Authorisation VO-R/1
Additional information Railways systems. An operator according to the law 77/2002. Terminals. Duplex 45 MHz, paired to 921.1-924.9 MHz. 876.1-879.9 MHz with the channel raster 200 kHz. DMO with the channel raster 12.5 kHz on 876.0125 MHz, 876.025 MHz, 876.0375 MHz, 876.05 MHz, 876.0625 MHz. 879.9-880 MHz is the guard band.
Application Digital cellular
Section 880 – 915 MHz
Harmonisations 2009/766/EC, 2011/251/EU, 2009/114/EC, 2018/637/EU
Authorisation VO-R/1
Additional information Systems of electronic communication services, GSM or compatible. Three countrywide networks. The number of the rights to use frequencies limited. FDD, duplex 45 MHz. Terminals.
Application Digital cellular
Section 880 – 915 MHz
Authorisation VO-R/24
Additional information Repeaters inside trains. For the details see the General Authorisation.
Application Non-specific SRDs
Section 862 – 863 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 3
Additional information 25 mW e.r.p. For detail conditions consult General Authorisation.
Application Wireless audio/multimedia
Section 863 – 865 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 10
Additional information Power max 10 mW e.r.p.
Application Wideband data transmission systems
Section 863 – 868 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10
Additional information E.r.p. 25 mW. For detail conditions consult General Authorisation.
Application Non-specific SRDs
Section 863 – 870 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 3
Additional information Max. e.r.p. 25 mW. For detail conditions consult General Authorisation.
Application Wireless audio/multimedia
Section 864.8 – 865 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 10
Additional information E.r.p. 10mW, channel 50 kHz. Narrowband voice devices.
Application RFID
Section 865 – 868 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 11
Additional information Power max 100 mW e.r.p. For detail conditions consult General Authorisation.
Application RFID
Section 865.6 – 867.6 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 11
Additional information Power max 2 W e.r.p. For detail conditions consult General Authorisation.
Application Tracking, tracing and data acquisition
Section 865.6 – 865.8 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10
Additional information Power 500 mW e.r.p. For detail conditions consult General Authorisation.
Application Tracking, tracing and data acquisition
Section 866.2 – 866.4 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10
Additional information Power 500 mW e.r.p. For detail conditions consult General Authorisation.
Application Tracking, tracing and data acquisition
Section 866.8 – 867 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10
Additional information Power 500 mW e.r.p. For detail conditions consult General Authorisation.
Application Tracking, tracing and data acquisition
Section 867.4 – 867.6 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10
Additional information Power 500 mW e.r.p. For detail conditions consult General Authorisation.
Application RFID
Section 867.6 – 868 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 11
Additional information Power max 500 mW e.r.p. For detail conditions consult General Authorisation.
Application Non-specific SRDs
Section 868 – 868.6 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 3
Additional information Max e.r.p. 25 mW. For detail conditions consult General Authorisation.
Application Alarms
Section 868.6 – 868.7 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 7
Additional information Power max 10 mW e.r.p. For detail conditions consult General Authorisation.
Application Non-specific SRDs
Section 868.7 – 869.2 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 3
Additional information Max e.r.p. 25 mW. For detail conditions consult General Authorisation.
Application Alarms
Section 869.2 – 869.25 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 7
Additional information Power max 10 mW e.r.p. For detail conditions consult General Authorisation.
Application Alarms
Section 869.25 – 869.3 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 7
Additional information Power max 10 mW e.r.p. For detail conditions consult General Authorisation.
Application Alarms
Section 869.3 – 869.4 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 7
Additional information Power max 10 mW e.r.p. For detail conditions consult General Authorisation.
Application Non-specific SRDs
Section 869.4 – 869.65 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 3
Additional information Max. e.r.p. 500 mW. For detail conditions consult General Authorisation.
Application Alarms
Section 869.65 – 869.7 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 7
Additional information Power max 25 mW e.r.p. For detail conditions consult General Authorisation.
Application Non-specific SRDs
Section 869.7 – 870 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 3
Additional information Max. e.r.p. 5 mW. For detail conditions consult General Authorisation.
Application Non-specific SRDs
Section 869.7 – 870 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 3
Additional information Max. e.r.p. 25 mW. For detail conditions consult General Authorisation.
Application Non-specific SRDs
Section 870 – 875.8 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 3
Additional information Max. e.r.p. 25 mW. For detail conditions consult General Authorisation.
Application Non-specific SRDs
Section 870 – 876 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10 Art. 3
Additional information Max. e.r.p. 25 mW. For detail conditions consult General Authorisation.
Application Tracking, tracing and data acquisition
Section 874 – 874.4 MHz
Harmonisations CEPT/ERC/REC 70-03, 2019/1345
Authorisation VO-R/10
Additional information E.r.p. 500 mW. For detail conditions consult General Authorisation.
Application GPR/WPR
Section 230 – 1,000 MHz
Harmonisations CEPT/ERC/REC 70-03, CEPT/ECC/DEC/(06)08, 2019/1345
Authorisation VO-R/10 Art. 6
Additional information Ultra-wideband radars for screening of the structute of walls and earth´s surface (GPR/WPR). Maximum spectral density e.i.r.p.is -65 dBm/MHz, max. peak e.r.p. is -44.5 dBm/120 kHz.